Method · version 2, 17 Oct 2026
How the figures are made
We record the charger status that public feeds publish, keep every snapshot, and add up how long each charger spent in each status.
Status classes
- Available
- The feed shows the charger as free to use (AVAILABLE; in France
en_servicewithlibreor unknown occupancy). - In use
- Charging, reserved, or blocked (OCPI “blocked” means something stands in the way, usually a parked car); in France
en_servicewithoccupeorreserve. The charger is in service. - Out of service
- The feed shows the charger as out of order, inoperative, faulted or unavailable; in France
hors_service. This is the feed’s own status. - No recent report
- UNKNOWN, or no report for more than 24 hours (assumed threshold), or a period when our own archive has no recent snapshot of the feed. It is left out of reported availability and shown beside it.
- Not counted
- Planned, removed, or gone from the feed: not an operating charger.
Reported availability
For a period and a set of chargers: (time available + time in use) ÷ (time available + time in use + time out of service), summed over the chargers. The share of time with no recent report is shown with every figure, so a high value built on few reports is visible as such.
Planned maintenance: the feeds have no separate status for it. A charger the feed shows as out of service during maintenance counts as out of service; one shown as planned or removed is not counted.
Per feed
| Country | Feed | Polled | “Last report” is | Change time |
|---|---|---|---|---|
| Germany | MobiData BW OCPDB | every 15 minutes (changes since the last poll), plus a full snapshot every 12 hours | the later of the source's own last real-time update and the charger's own last status change (OCPDB publishes no per-charger heartbeat) | status_last_updated |
| France | IRVE dynamique (transport.data.gouv.fr) | every hour | the row’s own timestamp (horodatage) | horodatage |
| Finland | Fintraffic Digitraffic AFIR | every 15 minutes | lastUpdatedAt, which the feed refreshes without a status change | modifiedAt |
| Lithuania | Via Lietuva (ev.vialietuva.lt) | every 15 minutes | the site’s lastUpdated, which live sites refresh every few minutes | the site’s lastUpdated |
- Change times. Where a feed gives the time of a status change, we use it, kept within the interval between our previous snapshot and the one that showed the change, and within the snapshot’s UTC day. Otherwise the snapshot time is used.
- Archive gaps. If we have no snapshot of a feed for longer than three poll periods (Germany: 12 hours, the window its change lists cover), that time is “no recent report” for every charger in the feed.
- Identity. Chargers are matched by the feed’s own identifier: the EVSE id in Finland and France, the OCPDB charger id in Germany, the station and refill point in Lithuania. Sites and operators come from each country’s static open data, refreshed daily.
- Aggregators. Several German sources are data aggregators, not operators. We say “status as published in” the feed, never that an operator reported it.
- Publication per source. We publish only sources with an open licence (see Sources). Feeds from the Netherlands, Portugal, Greece and Switzerland, and four German sources, are archived for method checks only and never shown.
Accuracy check
Checked 17 Oct 2026, 15:03 UTC: an independent re-read of the four source feeds matched our published counts exactly for Finland and Lithuania, to within 1 charger in 114,930 for France, and to within 0.8 % per status for Germany. 100 randomly chosen chargers were classified identically. This check covers status only, not prices.
Versions
- Version 2, 17 Oct 2026. Germany: a charger’s own status change also counts as a report, so a source whose real-time timestamp lags does not turn chargers with live status changes into “no recent report”. The share of German chargers with no status change for 30 days is shown on the Germany page.
- Version 1, 14 Oct 2026. First version.
Source changes
Days on which the sources counted for a country changed. A step in that country’s series on such a day is a change of sources, not of the network. The downloads mark these days in sources_changed.
- Germany, 3 Nov 2026: One source (54 chargers) is left out from this day: it no longer states a licence.
- Germany, 8 Nov 2026: Two more sources under CC0 are counted from this day, about 4,200 chargers.
Reported status is not real availability
These feeds carry what each network’s back-end systems report. A charger can be reported available and still not deliver energy. In a case study of a European operator with 1,500 DC chargers, measured availability stayed about 13 points below the uptime its systems reported (Virta). Monta finds that about 90 % of European charging sessions deliver energy (eeNews Europe), and P3 notes there is no uniform cross-country definition of uptime (P3). Read our figures as an upper bound.
Errors and disputes
Every snapshot is kept, so any figure can be checked against what the feed published. To report an error, see Contact and disputes. Corrections are dated and listed on Corrections; errors on our side (parsing, matching) are also logged on Status.